VoltGuard600™ Power Cables

Building Wire Solutions for The Electrical Construction Industry

Remee offers a variety of VoltGuard600™ power cables for use as building wire for commercial, industrial and residential installations. Choose from any of these power cable families for the type needed for your application.

Download the VoltGuard600™ Building Wire Brochure

XHHW-2 Wire

XHHW-2 is a type of electrical wire commonly used in building and industrial applications. The acronym stands for “Cross-linked High Heat-Resistant Water-Resistant wire – version 2. It meets stricter performance standards than standard XHHW wire.

Key Features of XHHW-2 Wire

  • Temperature rating: From -40°C to +90°C in wet or dry conditions
  • Voltage rating: Typically, 600V or 1000V depending on specifications
  • Durability: Resistant to chemicals, abrasion, and sunlight

Key Benefits of XHHW-2 Wire

1. High Temperature Resistance

  • Rated from -40°C to +90°C (194°F) in both dry and wet locations
  • Suitable for high-heat environments, making it more versatile than
    THHN in certain applications

2. Superior Moisture Resistance

  • The insulation is designed to resist water, which makes it ideal for wet locations and conduit installations where moisture may be present

3. Excellent Dielectric Strength

  • The cross-linked polyethylene (XLPE) insulation provides high dielectric strength, enhancing electrical safety and reducing the risk of insulation failure

Uses and Applications of XHHW-2 Wire

1. Commercial and Industrial Wiring
2. Underground Installations
3. Service Entrance
4. Industrial Control Panels and Machinery

Img

RHH/RHW-2/USE-2 Cable

RHH, RHW-2 and USE-2 cables are types of electrical wire with specific insulation and performance characteristics defined by the National Electrical Code (NEC).

RHH = Rubber insulation, high heat resistance (up to 90°C in dry locations)
RHW-2 = Rubber insulation, heat resistant, water resistant (suitable for wet locations), rated or -40°C to +90°C in both wet and dry locations.
USE-2 (Underground Service Entrance, Type 2) wire is designed specifically for underground and outdoor electrical distribution, with a focus on durability in harsh conditions.

Key Features of RHH/RHW-2/USE-2 Cable

  • Conductor: Typically copper (sometimes aluminum)
  • Insulation: Cross-linked polyethylene (XLP or XLPE), which provides durability and resistance to heat, moisture, sunlight, and chemicals
  • Voltage Rating: 600V/1kV
  • Temperature Rating: RHH: -40°C to +90°C (dry); RHW-2 & USE-2:
    -40°C to +90°C (dry and wet)

Key Benefits of RHH/RHW-2/USE-2 Cable

  • High temperature rating (90°C dry/wet)
  • Moisture resistance (especially RHW-2)
  • Chemical and abrasion resistance
  • Flexible for easier handling and installation
  • Approved for use in NEC-compliant systems

Uses and Applications of RHH/RHW-2/USE-2 Cable

  1. Power Distribution
  2. Conduit and Raceway Systems
  3. Underground Installations
  4. Industrial Facilities
  5. Utility and Substation Work
  6. Switchgear and Panelboard Wiring
  7. Outdoor Applications
  8. Industrial Power Distribution
  9. Subpanel or Detached Structure Feed

USE-2 Applications:

Limitations:

  • Not rated for interior building use unless run through conduit all the
    way and specifically rated as USE-2/RHH/RHW-2
  • Not suitable for use above ground in conduit within buildings
    unless specifically rated as USE-2/RHH/RHW-2

Uses and Applications of USE-2 Wire

  1. Underground Service Entrance
  2. Outdoor Applications
  3. Industrial Power Distribution
  4. Subpanel or Detached Structure Feed
Img

THWN-2/THHN Wire

THWN-2 (Thermoplastic Heat and Water resistant Nylon-coated) wire is one of the most common and versatile electrical wires used in residential, commercial, and industrial applications.

Features:

  • Insulation: PVC with nylon jacket
  • Rated: 600V, -40°C to +90°C dry and wet
  • Nylon over PVC insulation
  • Very thin insulation compared to XLPE-based wires
  • Good abrasion and chemical resistance from nylon jacket
  • More versatile since it can handle both wet (if in conduit) and dry
    installations
  • Sunlight resistant
  • Thin, Lightweight Insulation – Easier to pull through conduit and requires less space
  • Cost-Effective – Generally cheaper than XHHW-2 or USE-2 for indoor applications
  • Versatile for Indoor Use – Commonly used for conduit, panel, and control wiring in buildings
  • Oil, Gas & Chemical Resistant – Nylon jacket adds extra protection against corrosion and abrasion

THHN (Thermoplastic High Heat-resistant Nylon-coated) wire is one of the most common and versatile electrical wires used in residential, commercial, and industrial applications.

Features:

  • Insulation: PVC with nylon jacket
  • Rated: 600V, 90°C dry
  • Nylon over PVC insulation
  • Very thin insulation compared to XLPE-based wires
  • Good abrasion and chemical resistance from nylon jacket
  • More versatile since it can handle both wet (if in conduit)and dry
    installations
  • Sunlight resistant
  • Thin, Lightweight Insulation – Easier to pull through conduit and requires less space
  • Cost-Effective – Generally cheaper than XHHW-2 or USE-2 for indoor applications
  • Versatile for Indoor Use – Commonly used for conduit, panel, and control wiring in buildings
  • Oil, Gas & Chemical Resistant – Nylon jacket adds extra protection against corrosion and abrasion

Limitations

  • Must be installed in conduit (not rated for free air or direct burial)
  • Nylon jacket can be damaged more easily during pulling if not properly lubricated

Benefits of THWN-2 Wire

  1. High Temperature Rating – Rated up to 90°C (194°F) in dry locations
  2. Thin, Lightweight Insulation – Easier to pull through conduit and requires less space.
  3. Cost-Effective – Generally cheaper than XHHW-2 or USE-2 for indoor applications.
  4. Versatile for Indoor Use – Commonly used for conduit, panel, and control wiring in buildings.
  5. Oil, Gas & Chemical Resistant – Nylon jacket adds extra protection
    against corrosion and abrasion.
  6. Widely Available – One of the most commonly stocked and installed wire types.
  7. Multiple Conductors & Colors – Available in a variety of sizes and
    colors for easy circuit identification.

Uses & Applications of THHN Wire

  1. Building Wiring
  2. Control Wiring
  3. Conduit Installations
  4. Lighting and Outlet Circuits
  5. Industrial Power Distribution
Img

Copper Ground Wire

VoltGuard600™ ground wire features copper and tinned copper solid and stranded conductors with insulation options.

Img

Building Wire Comparison Chart

Use the chart below to select the right building wire product for your application.

Specifications
THHN (See THWN-2)
THWN-2 (Multi-listed including THHN)
XHHW-2
USE-2 (See RHW-2)
RHH (See RHW-2)
RHW-2 (Multi-listed including RHH and USE-2 )
Wire Type
THHN (See THWN-2)
THWN-2 (Multi-listed including THHN)
XHHW-2
USE-2 (See RHW-2)
RHH (See RHW-2)
RHW-2 (Multi-listed including RHH and USE-2 )
UL Type
UL 83
UL 83
UL 44
UL 854
UL 44
UL 44
Insulation Material
PVC insulation with nylon jacket
PVC insulation with nylon jacket
Cross-linked polyethylene (XLPE)
Cross-linked polyethylene (XLPE)
Cross-linked polyethylene (XLPE)
Cross-linked polyethylene (XLPE)
Voltage Rating
600V
600V
600V/1kV
600V
1000V
1000V
High Temp. Rating
90°C dry, (& 90°C wet dual-listed)
90°C wet/dry
90°C wet/dry
90°C wet/dry
90°C dry, (& 90°C wet multi-listed)1
90°C wet/dry
Low Temp. Rating
-40°C wet/dry
-40°C wet/dry
-40°C wet/dry
-40°C wet/dry
-40°C wet/dry
-40°C wet/dry
Wet Location Use
Yes, because dual-listed
Yes
Yes
Yes
Yes, because multi-listed
Yes
Nom. Insulation Thickness
15 - 70 mils (varies by AWG)
15 - 70 mils (varies by AWG)
30 to 80 mils (varies by AWG)
45 - 110 mils (varies by AWG)
45 - 110 mils (varies by AWG)
45 - 110 mils (varies by AWG)
Min. Jacket Thickness
4 - 9 mils (varies by AWG)
4 - 9 mils (varies by AWG)
N/A
N/A
N/A
N/A
Key Features

Thin insulation, high flexibility, sunlight resistant, cost-effective

Dual-rated (THHN/THWN-2), versatile, sunlight resistant

High dielectric strength, sunlight resistant, flexible

Direct burial rated, sunlight resistant, OK for interior use above ground since milti-rated

Flame-resistant, thick insulation, sunlight resistant

Heat- and moisture-resistant, sunlight resistant, direct burial rated

Typical Applications

Conduit and raceways in dry locations, plus same as THWN-2

Conduit and raceways, feeders, branch circuits in wet/dry locations

Feeders and branch circuits in conduit, industrial, commercial, residential

Underground service entrance, direct burial, outdoor feeders, plus same as RHW-2

Dry locations in conduit and raceways, plus same as RHW-2

Underground service entrance, feeders, conduit, raceways, duct, wet/dry applications

Summary:

XHHW-2 = Balanced performance, moisture & chemical resistance. Best for long runs, harsh environments, wet/dry versatility.

RHH = Heavy insulation for heavy-duty protection, for indoor dry use only.

RHW-2 = Same as RHH but wet-rated, very durable (including burial).

USE-2 = For underground use only, such as underground service entrances.

THHN = Thin, cost-effective, easy to install; for indoor dry use only.

THWN-2 = Most versatile for general purpose use; handles both wet and dry applications.

Applications

VoltGuard600™ by Remee offers a variety of power cable types and sizes to meet a wide range of applications, including but not limited to:

  • Power Distribution
  • Building Wiring
  • Commercial and Industrial Wiring
  • Residential Construction
  • Underground Installations
  • Service Entrance
  • Industrial Control Panels and Machinery
  • Conduit and Raceway Systems
  • Utility and Substation Work
  • Switchgear and Panelboard Wiring
  • Subpanel or Detached Structure Feed
  • Control Wiring
  • Conduit Installations
  • Lighting and Outlet Circuits

XHHW-2 600V/1kV Cables

Product Type Product Description Rating Remee Part No. & Data Sheet
XHHW-2, 600V/1kV #14, 1 SOL BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW1401BCMUL
XHHW-2, 600V/1kV #14, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW1407BCMUL
XHHW-2, 600V/1kV #12, 1 SOL BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW1201BCMUL
XHHW-2, 600V/1kV #12, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW1207BCMUL
XHHW-2, 600V/1kV #10, 1 SOL BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW1001BCMUL
XHHW-2, 600V/1kV #10, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW1007BCMUL
XHHW-2, 600V/1kV #8, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW0807BCMUL
XHHW-2, 600V/1kV #6, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW0607BCMUL
XHHW-2, 600V/1kV #4, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW0407BCMUL
XHHW-2, 600V/1kV #3, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW0307BCMUL
XHHW-2, 600V/1kV #2, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW0207BCMUL
XHHW-2, 600V/1kV #1, 19 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW0119BCMUL
XHHW-2, 600V/1kV 1/0, 19 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW1/019BCMUL
XHHW-2, 600V/1kV 2/0, 19 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW2/019BCMUL
XHHW-2, 600V/1kV 3/0, 19 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW3/019BCMUL
XHHW-2, 600V/1kV 4/0, 19 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW4/019BCMUL
XHHW-2, 600V/1kV 250, 37 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW25037BCMUL
XHHW-2, 600V/1kV 300, 37 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW30037BCMUL
XHHW-2, 600V/1kV 350, 37 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW35037BCMUL
XHHW-2, 600V/1kV 400, 37 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW40037BCMUL
XHHW-2, 600V/1kV 500, 37 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW50037BCMUL
XHHW-2, 600V/1kV 600, 61 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW60061BCMUL
XHHW-2, 600V/1kV 700, 61 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW70061BCMUL
XHHW-2, 600V/1kV 750, 61 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW75061BCMUL
XHHW-2, 600V/1kV 1000, 61 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 1581, RW90, CSA C22.2 No. 38 XHHW100061BCMUL
*Tinned copper conductors are also available.
1/0 AWG and larger CT FT-4

RHH, RHW-2, USE-2 600V/1kV Cables

Product Type Product Description Rating Remee Part No. & Data Sheet
RHH, RHW-2, USE-2 600V/1kV #14, 1 SOL BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH1401BCMUL
RHH, RHW-2, USE-2 600V/1kV #14, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH1407BCMUL
RHH, RHW-2, USE-2 600V/1kV #12, 1 Sol BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH1201BCMUL
RHH, RHW-2, USE-2 600V/1kV #12, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH1207BCMUL
RHH, RHW-2, USE-2 600V/1kV #10, 1 SOL BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH1001BCMUL
RHH, RHW-2, USE-2 600V/1kV #10, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH1007BCMUL
RHH, RHW-2, USE-2 600V/1kV #8, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH0807BCMUL
RHH, RHW-2, USE-2 600V/1kV #6, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH0607BCMUL
RHH, RHW-2, USE-2 600V/1kV #4, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH0407BCMUL
RHH, RHW-2, USE-2 600V/1kV #3, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH0307BCMUL
RHH, RHW-2, USE-2 600V/1kV #2, 7 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH0207BCMUL
RHH, RHW-2, USE-2 600V/1kV #1, 19 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH0119BCMUL
RHH, RHW-2, USE-2 600V/1kV 1/0, 19 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH1/019BCMUL
RHH, RHW-2, USE-2 600V/1kV 2/0, 19 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH2/019BCMUL
RHH, RHW-2, USE-2 600V/1kV 3/0, 19 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH3/019BCMUL
RHH, RHW-2, USE-2 600V/1kV 4/0, 19 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH4/019BCMUL
RHH, RHW-2, USE-2 600V/1kV 250, 37 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH25037BCMUL
RHH, RHW-2, USE-2 600V/1kV 300, 37 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH30037BCMUL
RHH, RHW-2, USE-2 600V/1kV 350, 37 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH35037BCMUL
RHH, RHW-2, USE-2 600V/1kV 400, 37 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH40037BCMUL
RHH, RHW-2, USE-2 600V/1kV 500, 37 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH50037BCMUL
RHH, RHW-2, USE-2 600V/1kV 600, 61 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH60037BCMUL
RHH, RHW-2, USE-2 600V/1kV 700, 61 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH70037BCMUL
RHH, RHW-2, USE-2 600V/1kV 750, 61 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH75037BCMUL
RHH, RHW-2, USE-2 600V/1kV 1000, 61 Str BC, NS, XLPE ins NFPA 70, UL 44, UL 854, UL 1581 RHH100037BCMUL
*Tinned copper conductors are also available.

THWN-2/THHN 600V Cables

Product Type Product Description Rating Remee Part No. & Data Sheet
THHN/THWN-2 600V #14, 1 SOL BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN1401BCMUL
THHN/THWN-2 600V #14, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN1419BCMUL
THHN/THWN-2 600V #12, 1 SOL BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN1201BCMUL
THHN/THWN-2 600V #12, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN1219BCMUL
THHN/THWN-2 600V #10, 1 SOL BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN1001BCMUL
THHN/THWN-2 600V #10, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN1019BCMUL
THHN/THWN-2 600V #8, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN0819BCMUL
THHN/THWN-2 600V #6, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN0619BCMUL
THHN/THWN-2 600V #4, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN0419BCMUL
THHN/THWN-2 600V #3, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN0319BCMUL
THHN/THWN-2 600V #2, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN0219BCMUL
THHN/THWN-2 600V #1, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN0119BCMUL
THHN/THWN-2 600V 1/0, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN1/019BCMUL
THHN/THWN-2 600V 2/0, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN2/019BCMUL
THHN/THWN-2 600V 3/0, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN3/019BCMUL
THHN/THWN-2 600V 4/0, 19 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN4/019BCMUL
THHN/THWN-2 600V 250, 37 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN25037BCMUL
THHN/THWN-2 600V 300, 37 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN30037BCMUL
THHN/THWN-2 600V 350, 37 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN35037BCMUL
THHN/THWN-2 600V 400, 37 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN40037BCMUL
THHN/THWN-2 600V 500, 37 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN50037BCMUL
THHN/THWN-2 600V 600, 61 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN60061BCMUL
THHN/THWN-2 600V 700, 61 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN70061BCMUL
THHN/THWN-2 600V 750, 61 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN75061BCMUL
THHN/THWN-2 600V 1000, 61 Str BC, NS, PVC ins, Nylon jkt NFPA 70,UL 83, UL 1581, C(UL) THHN100061BCMUL
*Tinned copper conductors are also available.

BC & TC Solid & Stranded Ground Wire

Product Type Product Description Rating Remee Part No. & Data Sheet
Copper Ground Wire Bare Copper and Tinned Copper Solid and Stranded Conductors in a variety of sizes ASTM B 1, B 2, B 3, B 8, and B 33 RM-CUXXXXXXYC

Also see Renewables™ by Remee for additional power cables.

How Can Remee Help?

Wire & Cable with Personal Service

Request for Information/Quote

Whether you have an RFI, RFQ, or RFP, let us know here and we will respond quickly.

Request Info

Ask a Cable Expert

Ask our team any question you may have on selecting or designing the right cable for your application.

Ask An Expert

Talk to a Remee Exec

Our executive team is readily accessible to you.  Use this form to express any information or question to our management team.

Reach A Remee Executive

Customize a Cable

Want us to modify a standard cable or custom design one for you? Just complete this form and we promise to have a quote to you within 48 hours.

Customize A Cable Request

Contact Us

Cannot find what you are looking for?

Contact Us

    Newsletter Sign-up